All Transistors. SCR. BTA12-600B Datasheet

 

BTA12-600B Triac DATASHEET

BTA12-600B ELECTRICAL SPECIFICATIONS

 

   Type: Triac
   Maximum repetitive peak and off-state voltage (VDRM): 600 V
   Maximum average on-state current (IT(AVR)): 12 A
   Maximum RMS on-state current (IT(RMS)): 12 A
   Non repetitive surge peak on-state current (ITSM): 120 A
   Triggering gate voltage (VGT): 1.3 V
   Peak on-state voltage drop (VTM): 1.55 V
   Triggering gate current (IGT): 50 mA

 

BTA12-600B Replacements

Type
< PGM < W
< VDRM < V
< IT(AVR) < A
< IT(RMS) < A
< ITSM < A
< dI/dt < A/µs
< dV/dt < V/µs
Tstg, Tj > °C
RTH(j-a) < K/W
RTH(j-c) < K/W
VGT < V
VTM < V
IGT < mA
IH < mA
Package + similar ones

  - Replacements for SCR and Triac

 

BTA12-600B Datasheet

Page #1

BTA12-600B
 datasheet

Page #2

BTA12-600B
 datasheet #2

Description

BTA/BTB12 and T12 Series SNUBBERLESS™, LOGIC LEVEL & STANDARD 12A TRIACS MAIN FEATURES: A2 Symbol Value Unit IT(RMS) 12 A G VDRM/VRRM A1 600 and 800 V A2 IGT (Q1) 5 to 50 mA DESCRIPTION A1 A2 Available either in through-hole or surface-mount G packages, the BTA/BTB12 and T12 triac series is suitable for general purpose AC switching. They D2PAK can be used as an ON/OFF function in (T12-G) applications such as static relays, heating regulation, induction motor starting

 