SI2306 Datasheet and Replacement
Type Designator: SI2306
Marking Code: A69TF
Type of Transistor: MOSFET
Type of Control Channel: N -Channel
Pd ⓘ - Maximum Power Dissipation: 1.25 W
|Vds|ⓘ - Maximum Drain-Source Voltage: 30 V
|Vgs|ⓘ - Maximum Gate-Source Voltage: 15 V
|Vgs(th)|ⓘ - Maximum Gate-Threshold Voltage: 3 V
|Id| ⓘ - Maximum Drain Current: 3.5 A
Tj ⓘ - Maximum Junction Temperature: 150 °C
Qg ⓘ - Total Gate Charge: 4.2 nC
tr ⓘ - Rise Time: 7.5 nS
Cossⓘ - Output Capacitance: 120 pF
Rds ⓘ - Maximum Drain-Source On-State Resistance: 0.057 Ohm
Package: SOT23
SI2306 substitution
SI2306 Datasheet (PDF)
si2306.pdf

Shenzhen Tuofeng Semiconductor Technology Co., Ltd Si2306N-Channel 30-V (D-S) MOSFETPRODUCT SUMMARYVDS (V) rDS(on) (W) ID (A)FEATURES0.057 @ VGS = 10 V 3.5D Power MOSFET30300.094 @ VGS = 4.5 V 2.8D 100% Rg Tested-TO-236(SOT-23)G 13 DS 2Top ViewSi2306 *Marking CodeOrdering Information: Si2306DS-T1ABSOLUTE MAXIMUM RATINGS (TA = 25_C UNLESS OTHERWISE NOT
si2306.pdf

SI2306(BRCS2306M) Rev.C Feb.-2015 DATA SHEET / Descriptions SOT-23 N MOS N- CHANNEL MOSFET in a SOT-23 Plastic Package. / Features , MOS Trench FET Power MOSFET 100% Rg Tested. / Applications Primarily the display screen drive applications.
si2306 ki2306.pdf

SMD Type MOSFETICN-Channel 30-V (D-S) MOSFETSI2306 (KI2306)SOT-23-3Unit: mm+0.22.9 -0.1+0.10.4-0.1 Features3 VDS (V) = 30V RDS(ON) 57m (VGS =-10V) RDS(ON) 94 m (VGS =-4.5V)1 2+0.02+0.1D 0.15 -0.020.95 -0.1+0.11.9 -0.2G 1. Gate2. SourceS 3. DrainAbsolute Maximum Ratings Ta = 25Parameter Symbol Rating Unit Drain-S
si2306.pdf

Plastic-Encapsulate MosfetsFEATURESSI2306Lower on-resistanceN-Channel MOSFETReliable and RuggedAbsolute Maximum Ratings (TA=25oC, unless otherwise noted)Parameter Symbol Ratings UnitDrain-Source Voltage VDS 30 VGate-source Voltage VGS 20 V1.GateDrain Current (Continuous) ID 3.16 A 2.SourceSOT-233.DrainDrain Current (Pulsed)a IDM 10 AoTotal Power Dissipation @TA=2
Datasheet: FMP36-015P , FMP76-01T , GMM3x100-01X1-SMD , FDMS0306AS , GMM3x120-0075X2-SMD , FDMS0300S , GMM3x160-0055X2-SMD , FDMC7200S , CS150N03A8 , FDMC7200 , GMM3x60-015X2-SMD , FDMC0310AS , GWM100-0085X1-SL , FDMS3610S , GWM100-0085X1-SMD , FDMS3606S , GWM100-01X1-SL .
History: PJP2NA60 | PJP7NA65 | PJF10NA65 | ST3406SRG | KI502DT | PJP12NA60 | TF2306
Keywords - SI2306 MOSFET datasheet
SI2306 cross reference
SI2306 equivalent finder
SI2306 lookup
SI2306 substitution
SI2306 replacement
History: PJP2NA60 | PJP7NA65 | PJF10NA65 | ST3406SRG | KI502DT | PJP12NA60 | TF2306



LIST
Last Update
MOSFET: DHS045N88B | DHS045N88 | DHS045N85I | DHS045N85F | DHS045N85E | DHS045N85D | DHS045N85B | DHS045N85 | DHS044N12U | DHS044N12E | DHS044N12 | DHS043N85P | DHS043N07P | DHS042N85P | DHS042N15E | DHS042N15
Popular searches
p75nf75 | d880 transistor | 2sc1845 | p60nf06 | 2sa1837 | ksc1845 transistor | irf630 datasheet | mpsa13 equivalent