P06P03LDG Datasheet. Specs and Replacement

Type Designator: P06P03LDG  📄📄 

Type of Transistor: MOSFET

Type of Control Channel: P-Channel

Absolute Maximum Ratings

Pd ⓘ - Maximum Power Dissipation: 48 W

|Vds|ⓘ - Maximum Drain-Source Voltage: 30 V

|Vgs|ⓘ - Maximum Gate-Source Voltage: 20 V

|Id| ⓘ - Maximum Drain Current: 12 A

Tj ⓘ - Maximum Junction Temperature: 150 °C

Electrical Characteristics

tr ⓘ - Rise Time: 10 nS

Cossⓘ - Output Capacitance: 135 pF

RDSonⓘ - Maximum Drain-Source On-State Resistance: 0.045 Ohm

Package: TO252

  📄📄 Copy 

P06P03LDG substitution

- MOSFET ⓘ Cross-Reference Search

 

P06P03LDG datasheet

 ..1. Size:492K  unikc
p06p03ldg.pdf pdf_icon

P06P03LDG

P06P03LDG P-Channel Enhancement Mode MOSFET PRODUCT SUMMARY V(BR)DSS RDS(ON) ID -30V 45m @VGS = -10V -12A TO-252 ABSOLUTE MAXIMUM RATINGS (TA = 25 C Unless Otherwise Noted) PARAMETERS/TEST CONDITIONS SYMBOL LIMITS UNITS VDS Drain-Source Voltage -30 V VGS Gate-Source Voltage 20 TC = 25 C -12 ID Continuous Drain Current TC = 100 C -10 A IDM -30 Pulsed Drain C... See More ⇒

 ..2. Size:492K  niko-sem
p06p03ldg.pdf pdf_icon

P06P03LDG

P06P03LDG P-Channel Enhancement Mode MOSFET PRODUCT SUMMARY V(BR)DSS RDS(ON) ID -30V 45m @VGS = -10V -12A TO-252 ABSOLUTE MAXIMUM RATINGS (TA = 25 C Unless Otherwise Noted) PARAMETERS/TEST CONDITIONS SYMBOL LIMITS UNITS VDS Drain-Source Voltage -30 V VGS Gate-Source Voltage 20 TC = 25 C -12 ID Continuous Drain Current TC = 100 C -10 A IDM -30 Pulsed Drain C... See More ⇒

 7.1. Size:315K  1
p06p03lcg.pdf pdf_icon

P06P03LDG

P-Channel Logic Level Enhancement P06P03LCG NIKO-SEM Mode Field Effect Transistor SOT-89 Lead-Free D PRODUCT SUMMARY 1. GATE V(BR)DSS RDS(ON) ID 2. DRAIN G 3. SOURCE -30 45m -4A S ABSOLUTE MAXIMUM RATINGS (TC = 25 C Unless Otherwise Noted) PARAMETERS/TEST CONDITIONS SYMBOL LIMITS UNITS Drain-Source Voltage VDS -30 V Gate-Source Voltage VGS 20 V TC = 25 C -4 ... See More ⇒

 7.2. Size:480K  unikc
p06p03lcga.pdf pdf_icon

P06P03LDG

P06P03LCGA P-Channel Enhancement Mode MOSFET PRODUCT SUMMARY V(BR)DSS RDS(ON) ID 45m @VGS = -10V -30V -4A SOT-89 ABSOLUTE MAXIMUM RATINGS (TA = 25 C Unless Otherwise Noted) PARAMETERS/TEST CONDITIONS SYMBOL LIMITS UNITS VDS Drain-Source Voltage -30 V VGS Gate-Source Voltage 20 TA = 25 C -4 ID Continuous Drain Current TA = 70 C -3 A IDM -20 Pulsed Drain Cur... See More ⇒

Detailed specifications: P0660AS, P0660AT, P0660ATF, P0690ATF, P0690ATFS, P06B03LVG, P06P03LCG, P06P03LCGA, 20N60, P06P03LVG, P9006EDG, P9006EI, P9006EL, P9006ESG, P9006ETF, P9006EVG, P0703BD

Keywords - P06P03LDG MOSFET specs

 P06P03LDG cross reference

 P06P03LDG equivalent finder

 P06P03LDG pdf lookup

 P06P03LDG substitution

 P06P03LDG replacement

Learn how to find the right MOSFET substitute. A guide to cross-reference, check specs and replace MOSFETs in your circuits.